644 research outputs found

    Maximum likelihood estimation in hidden Markov models with inhomogeneous noise.

    No full text
    We consider parameter estimation in finite hidden state space Markov models with time-dependent inhomogeneous noise, where the inhomogeneity vanishes sufficiently fast. Based on the concept of asymptotic mean stationary processes we prove that the maximum likelihood and a quasi-maximum likelihood estimator (QMLE) are strongly consistent. The computation of the QMLE ignores the inhomogeneity, hence, is much simpler and robust. The theory is motivated by an example from biophysics and applied to a Poisson- and linear Gaussian model

    The impact of audiovisual biofeedback on 4D functional and anatomic imaging: Results of a lung cancer pilot study.

    Get PDF
    BACKGROUND AND PURPOSE: The impact of audiovisual (AV) biofeedback on four dimensional (4D) positron emission tomography (PET) and 4D computed tomography (CT) image quality was investigated in a prospective clinical trial (NCT01172041). MATERIAL AND METHODS: 4D-PET and 4D-CT images of ten lung cancer patients were acquired with AV biofeedback (AV) and free breathing (FB). The 4D-PET images were analyzed for motion artifacts by comparing 4D to 3D PET for gross tumor volumes (GTVPET) and maximum standardized uptake values (SUVmax). The 4D-CT images were analyzed for artifacts by comparing normalized cross correlation-based scores (NCCS) and quantifying a visual assessment score (VAS). A Wilcoxon signed-ranks test was used for statistical testing. RESULTS: The impact of AV biofeedback varied widely. Overall, the 3D to 4D decrease of GTVPET was 1.2±1.3cm(3) with AV and 0.6±1.8cm(3) for FB. The 4D-PET increase of SUVmax was 1.3±0.9 with AV and 1.3±0.8 for FB. The 4D-CT NCCS were 0.65±0.27 with AV and 0.60±0.32 for FB (p=0.08). The 4D-CT VAS was 0.0±2.7. CONCLUSION: This study demonstrated a high patient dependence on the use of AV biofeedback to reduce motion artifacts in 4D imaging. None of the hypotheses tested were statistically significant. Future development of AV biofeedback will focus on optimizing the human-computer interface and including patient training sessions for improved comprehension and compliance

    BBMS + +  – basic bioinformatics meta-searcher

    Get PDF
    In this paper we present a Basic Bioinformatics Meta-searcher (BBMS), a web-based service aiming to simplify and integrate biological data searching through selected biological databases. BBMS facilitates biological data searching enabling multiple sources transparently, increasing research productivity as it avoids time consuming learning and parameterization of different search engines. As a complementary service, BBMS provides insight and links to common online bioinformatics tools. Users’ feedback when evaluating BBMS in terms of usability, usefulness and efficiency was very positive

    Pulmonary ventilation imaging based on 4-dimensional computed tomography: comparison with pulmonary function tests and SPECT ventilation images.

    Get PDF
    PURPOSE: 4-dimensional computed tomography (4D-CT)-based pulmonary ventilation imaging is an emerging functional imaging modality. The purpose of this study was to investigate the physiological significance of 4D-CT ventilation imaging by comparison with pulmonary function test (PFT) measurements and single-photon emission CT (SPECT) ventilation images, which are the clinical references for global and regional lung function, respectively. METHODS AND MATERIALS: In an institutional review board-approved prospective clinical trial, 4D-CT imaging and PFT and/or SPECT ventilation imaging were performed in thoracic cancer patients. Regional ventilation (V4DCT) was calculated by deformable image registration of 4D-CT images and quantitative analysis for regional volume change. V4DCT defect parameters were compared with the PFT measurements (forced expiratory volume in 1 second (FEV1; % predicted) and FEV1/forced vital capacity (FVC; %). V4DCT was also compared with SPECT ventilation (VSPECT) to (1) test whether V4DCT in VSPECT defect regions is significantly lower than in nondefect regions by using the 2-tailed t test; (2) to quantify the spatial overlap between V4DCT and VSPECT defect regions with Dice similarity coefficient (DSC); and (3) to test ventral-to-dorsal gradients by using the 2-tailed t test. RESULTS: Of 21 patients enrolled in the study, 18 patients for whom 4D-CT and either PFT or SPECT were acquired were included in the analysis. V4DCT defect parameters were found to have significant, moderate correlations with PFT measurements. For example, V4DCT(HU) defect volume increased significantly with decreasing FEV1/FVC (R=-0.65, P<.01). V4DCT in VSPECT defect regions was significantly lower than in nondefect regions (mean V4DCT(HU) 0.049 vs 0.076, P<.01). The average DSCs for the spatial overlap with SPECT ventilation defect regions were only moderate (V4DCT(HU)0.39 ± 0.11). Furthermore, ventral-to-dorsal gradients of V4DCT were strong (V4DCT(HU) R(2) = 0.69, P=.08), which was similar to VSPECT (R(2) = 0.96, P<.01). CONCLUSIONS: An 18-patient study demonstrated significant correlations between 4D-CT ventilation and PFT measurements as well as SPECT ventilation, providing evidence toward the validation of 4D-CT ventilation imaging

    Fast Orbit Feedback at BESSY II Performance and Operational Experiences

    Get PDF
    At the 3rd generation light source BESSY II the first phase of a fast orbit feedback system has been completed and put into operation in 2012. In this first phase the aim was to achieve noise suppression in the 1Hz to several 10Hz range, mostly avoiding expensive upgrades to existing hardware, such as beam position monitors and the CAN based setpoint transmission to the power supplies. Only the power supplies were replaced with newer, faster versions. This paper describes the capability of the phase I FOFB with respect to beam motion transient suppression, low frequency damping and high frequency noise generation as well as aspects of operational integration and stabilit

    The Phenotypic Radiation Resistance of CD44+/CD24−or low Breast Cancer Cells Is Mediated through the Enhanced Activation of ATM Signaling

    Get PDF
    Cancer initiating cells (CIC) are stem-like cells. CIC may contribute not only to the initiation of cancer but also to cancer recurrence because of the resistance of CIC both to chemotherapy and radiation therapy. From the MCF-7 and MDA-MB231 breast cancer cell lines and primary culture of patient breast cancer cells, we isolated by flow cytometry a CIC subset of cells with the CD44+/CD24−or low phenotype. The CD44+/CD24−or low subset showed increased sphere formation and resistance to radiation compared to the non- CD44+/CD24−or low subset. The increased radiation resistance was not dependent on the result of altered non-homologous end joining (NHEJ) DNA repair activity as both NHEJ activity and expression of the various proteins involved in NHEJ were not significantly different between the CD44+/CD24−or low and non- CD44+/CD24−or low subsets. However, activation of ATM signaling was significantly increased in CD44+/CD24−or low cells compared to non- CD44+/CD24−or low cells in both from breast cancer cell lines and primary human breast cancer cells. Application of an ATM inhibitor effectively decreased the radiation resistance of CD44+/CD24−or low subset, suggesting that targeting ATM signaling may provide a new tool to eradicate stem-like CIC and abolish the radiation resistance of breast cancer

    Localized bioconvection of Euglena caused by phototaxis in the lateral direction

    Full text link
    Euglena, a swimming micro-organism, exhibited a characteristic bioconvection that was localized at the center of a sealed chamber under bright illumination to induce negative phototaxis. This localized pattern consisted of high-density spots, in which convection was found. These observations were reproduced by a mathematical model that was based on the phototaxis of individual cells in both the vertical and lateral directions. Our results indicate that this convection is maintained by upward swimming, as with general bioconvection, and the localization originates from lateral phototaxis
    • …
    corecore